XTherm™- Type WHP
Job:
Engineer:
Contractor:
Prepared By:
Model:
Water Heaters
Models 1005-2005
Date:
Indoor/Outdoor:
97% Thermal Efficiency at Full Rate; Up to 99% at Part Load
100% Factory Fire Tested
Maximum Outlet Water Temperature: 160°F
Minimum Acceptable Inlet Water Temperature: 50°F
Full Safety Diagnostics with History
Footprint: Less Than 10.8 ft2
Limited Twenty-Five-Year Thermal Shock Warranty
Limited Ten-Year Primary Heat Exchanger Warranty
Limited Five-Year Secondary Heat Exchanger Warranty
Full Electronic Modulation, Constant Ratio 4:1 Turndown
Digital Controller with LCD Display
Status Display Lights
Heat Exchanger
Control (cont.)
Multi-Boiler Digital Temp Controllers
ƒ Bronze Headers
ƒ ASME HLW Stamped; 160 PSIG
MAWP
ƒ Diagnostics Panel with LCD Display,
2 lines, 20 characters
ƒ Digital Temperature Control
ƒ Water Temperature Sensors (3)
ƒ Cold Water Protection
B-36 TempTracker Mod+,
2-4 Water Heaters
B-37 TempTracker Mod+,
5-10 Water Heaters
B-38 TempTracker Mod+,
11-16 Water Heaters
ƒ National Board Listed
ƒ Cupro Nickel Fin Tubing
ƒ ASME Powder-Coated Tube Sheet
ƒ Silicone High Temp O-Rings
ƒ ASME Pressure Relief Valve
125 PSIG – Standard (Loose)
ƒ 150 PSI Air Vent, Auto
ƒ T&P Gauge (Loose)
ƒ Stainless Steel Secondary Heat
Exchanger
ƒ Stainless Steel Evaporator Plate
ƒ Boiler Pump: Bronze,
120V, 1∅, 60Hz
Burner
ƒ Ultra-Low NOx: Less than 20 PPM
(Natural Gas Only)
Options
F-10 Low Water Cut-Off, Remote
Probe
Gas Train
ƒ Fuel
I-5
High Limit, Manual Reset,
Adj., 100-200°F
Low Gas Pressure Switch,
Manual Reset
High Gas Pressure Switch,
Manual Reset
Natural Gas
Propane
ƒ Zero Governor Regulator
ƒ Dual-Seat Combination Valve
ƒ Electronic Firing Mode (WHP)
S-1
S-2
HP,
Z-12 Condensate Neutralizer Kit
Construction
ƒ Indoor/Outdoor Construction
ƒ Front Controls Enclosed
ƒ PolyTuf Powder Coat Finish
ƒ Rear Connections (Water, Gas, Vent,
Electrical, Comb. Air, Cond. Drain)
ƒ Combustion Air Filter
Control
Regulatory Agency Requirements
ƒ 120V, 60Hz, 1Ø, Power Supply
ƒ 120/24V 60Hz Transformer
ƒ Ignition Module
3-Try – Standard
Single-Try – Option C-6
ƒ Hot Surface Ignition (HSI)
ƒ Remote Flame Sensor
ƒ High Limit Control, Auto Reset
ƒ On/Off Power Switch
ƒ Flow Switch
ƒ Blocked Vent Pressure Switch
ƒ Combustion Air Proving Switch
ƒ Freeze Protection
ƒ Design Certified ANSI Z21.10.3/CSA 4.3
Venting
ƒ Vent Termination
Outdoor or Indoor, Vertical –
Option D-11
Indoor, Horizontal – Option D-15
ƒ Extractor - Optional
By others
ƒ Pump Switch
ƒ Pump Time Delay
ƒ Blocked Condensate Switch
Not required
Catalog No.: 6000.37
Effective: 9-15-08
Replaces: NEW
|
Rockford Fosgate RFP 1812 User Manual
Pioneer GM D7400M User Manual
Pioneer Car Stereo System AVH P6400CD User Manual
Philips TDA8566 User Manual
Philips SIC 4523 User Manual
PAC C2R GM29 User Manual
Life Fitness 90C User Manual
Konica Minolta DiMAGE S414 User Manual
Kenwood KAC 929 User Manual
JVC LYT1439 001B User Manual